Kern River Gas Transmission Company
Second Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 07/01/2000, Docket: RP00-288-000, Status: Effective
Original Sheet No. 732 Original Sheet No. 732 : Effective
RATE SCHEDULE MO-1
Kern River Firm Transportation Services
(Continued)
ARTICLE VI - MEASUREMENT OF GAS (Continued)
6.2 Measurement Procedures. (Continued)
6.2.3 Specific Gravity. The specific gravity of Gas flowing through
the meters shall be determined by means of a recording
gravitometer or gas chromatograph located at the delivering
party's measuring station or at any other point on said party's
system where there will be no commingling thereafter of Gas with
that delivered to the receiving party, and the arithmetic
average specific gravity each Day at such point shall be used in
computing deliveries of Gas during such Day at such point.
6.2.4 Flowing Temperature. The flowing temperature of the Gas
being metered shall be determined by means of a recording
thermometer installed and maintained in accordance with the
specifications set forth in Gas Measurement Committee Report No.
3, prepared by the Gas Measurement Committee of the American Gas
Association, dated September, 1985, or any subsequent revisions
thereof. The arithmetical average of readings each Day for the
time that Gas is flowing shall be deemed the Gas temperature and
used in computing the volumes of Gas metered during such Day.
6.2.5 Measurement. The volumetric unit of measurement for Gas
received or delivered hereunder shall be an Mcf of Gas at a base
temperature of 60 degrees Fahrenheit and at a base pressure of
14.73 Psia.