Kern River Gas Transmission Company

Second Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 07/01/2000, Docket: RP00-288-000, Status: Effective

Original Sheet No. 732 Original Sheet No. 732 : Effective

 

 

RATE SCHEDULE MO-1

Kern River Firm Transportation Services

(Continued)

 

ARTICLE VI - MEASUREMENT OF GAS (Continued)

 

6.2 Measurement Procedures. (Continued)

 

6.2.3 Specific Gravity. The specific gravity of Gas flowing through

the meters shall be determined by means of a recording

gravitometer or gas chromatograph located at the delivering

party's measuring station or at any other point on said party's

system where there will be no commingling thereafter of Gas with

that delivered to the receiving party, and the arithmetic

average specific gravity each Day at such point shall be used in

computing deliveries of Gas during such Day at such point.

 

6.2.4 Flowing Temperature. The flowing temperature of the Gas

being metered shall be determined by means of a recording

thermometer installed and maintained in accordance with the

specifications set forth in Gas Measurement Committee Report No.

3, prepared by the Gas Measurement Committee of the American Gas

Association, dated September, 1985, or any subsequent revisions

thereof. The arithmetical average of readings each Day for the

time that Gas is flowing shall be deemed the Gas temperature and

used in computing the volumes of Gas metered during such Day.

 

6.2.5 Measurement. The volumetric unit of measurement for Gas

received or delivered hereunder shall be an Mcf of Gas at a base

temperature of 60 degrees Fahrenheit and at a base pressure of

14.73 Psia.