Centra Pipelines Minnesota Inc.
Second Revised Volume No. 2
Contents / Previous / Next / Main Tariff Index
Effective Date: 10/16/1991, Docket: RP91-136-002, Status: Effective
Original Sheet No. 20 Original Sheet No. 20 : Effective
(a) The unit of volume, for the purpose of measurement, shall
be one (1) cubic foot of gas.
(b) The total heating value of the gas per cubic foot shall be
determined by an instrument of stamdard manufacture,
installed at an appropriate location, which measures the
heating value of the gas being delivered, or, if not installed
or operative, by sampling the gas at intervals of not more
than one (1) month. Such gas samples shall originate from
the gas stream from which gas is being received at Emerson,
Manitoba.
(c) The temperature of the gas passing through the meters shall
be determined by the use of an instrument of standard
manufacture so installed that it may properly record the
temperature of the gas flowing through the meters. The
temperature recorded during the period of time gas is
passing through the meter shall be used in computing gas
volumes.
(d) The specific gravity of the gas shall be determined by an
instrument of standard manufacture, either installed at an
appropriate location and which measures the specific gravity