Centra Pipelines Minnesota Inc.
Second Revised Volume No. 2
Contents / Previous / Next / Main Tariff Index
Effective Date: 10/16/1991, Docket: RP91-136-002, Status: Effective
Original Sheet No. 18 Original Sheet No. 18 : Effective
delivery of the gas and which do not cause it to fail to meet
any of the quality specifications herein set forth.
(c) Shall be commercially free from hydrogen sulphide,
containing not more than one (1) grain of hydrogen
sulphide per hundred cubic feet nor more than twenty (20)
grains of total sulphur per hundred cubic feet of gas as
determined by standard methods of testing.
(d) Shall not contain more than two per cent (2%) by volume
of carbon dioxide.
(e) Shall have been dehydrated, if necessary, for removal of
water present therein in a vapour state, and in no event
contain more than two point eight (2.8) grains of water
vapour per hundred cubic feet at standard conditions.
(f) Shall not exceed a temperature of one hundred and twenty
degree (120.) Fahrenheit.
7.2 Shipper shall ensure that the natural gas delivered to Centra shall
be odorized in order to comply with all state, federal and
provincial laws, orders, rules and regulations. Shipper shall be
responsible for any measurement of odorant level in the gas