Iroquois Gas Transmission System, L.P.
FIRST REVISED VOLUME NO. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 09/01/2003, Docket: RP03-420-000, Status: Effective
Original Sheet No. 107C Original Sheet No. 107C : Effective
(v) Intraday 2 Recall Notification.
(a) A Releasing Shipper recalling capacity should
provide notice of such recall to Transporter
and the first Replacement Shipper no later
than 2:30 p.m. on the day that Intraday 2
Nominations are due;
(b) Transporter should provide notification of
such recall to all affected Replacement
Shippers no later than 3:30 p.m. on the day
that Intraday 2 Nominations are due (Central
Clock Time);
The recall notification should include the quantity being
recalled expressed in terms of total released capacity
entitlements.
When a recall is done during the Intraday 1 or Intraday 2
recall notification periods, the allocation of capacity
between the Releasing Shipper and the Replacement Shipper(s)
shall be based upon the Elapsed Prorata Capacity. Elapsed
Prorata Capacity is that portion of the capacity that would
have theoretically been available for use prior to the
effective time of the intraday recall based upon a
cumulative uniform hourly use of the capacity.
Example: A Releasing Shipper has released 24,000 Dths to a
Replacement Shipper and has indicated in the offer that the
capacity is recallable. The Releasing Shipper subsequently
recalls the capacity. The following table shows the allocation
of capacity based on the recall notification cycle for the first
day of the recall. The Requested Recall Quantity is expressed
in terms of total released capacity entitlement. All quantities
are in Dekatherms.
Allocated Allocated
Recall Requested Releasing Replacement
Notification Recall Shipper Shipper
Cycle Quantity Capacity Capacity
Timely 24,000 24,000 0
Early Evening 24,000 24,000 0
Evening 24,000 24,000 0
Intraday 1 24,000 16,000 8,000
Intraday 2 24,000 12,000 12,000
For the remaining days of the recall, the capacity allocated to
the Releasing Shipper is 24,000 Dths and the capacity allocated
to the Replacement Shipper is 0 Dths.
(B) Reput Provisions. A Releasing Shipper may designate
capacity as reputable. When capacity is recalled, it
may not be reput for the same gas day. The deadline
for notifying Transporter of a reput is 8 AM Central
Clock Time to allow for timely nominations to flow on
the next gas day.