Guardian Pipeline, L.L.C.

Original Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 12/31/2008, Docket: RP09-80-000, Status: Effective

Original Sheet No. 216G Original Sheet No. 216G

 

GENERAL TERMS AND CONDITIONS

(Continued)

 

32B. ELECTRIC POWER COST RECOVERY SURCHARGE (Continued)

 

32B.4 Determination of the Electric Power Cost Recovery Surcharge

 

Transporter shall determine the current Electric Power Cost

Recovery Surcharge for each Seasonal Period by the following

procedure:

 

The estimated Electric Power Cost for each Seasonal Period shall

be summed with the balance accumulated in the Deferred Electric

Power Cost Account. For the Winter Period, the Electric Power

Cost Recovery Surcharge will be the estimated Winter Electric

Power Cost plus the balance accumulated in the Deferred Electric

Power Cost Account as of the prior August 31st. For the Summer

Period, the Electric Power Cost Recovery Surcharge will be the

estimated Summer Electric Power Cost plus the balance accumulated

in the Deferred Electric Power Cost Account as of the prior

January 31st. The applicable summed amounts for each Seasonal

Period shall then be divided by the Estimated Volumes for such

Seasonal Period to determine the Electric Power Cost Recovery

Surcharge for that Seasonal Period.

 

32B.5 Deferred Electric Power Cost Account

 

Transporter shall maintain the Deferred Electric Power Cost

Account in accordance with the following procedures:

 

(a) Transporter shall determine each month the actual Electric

Power Cost incurred, including those reflected in the then

effective Electric Power Cost Recovery Surcharge.

 

(b) Transporter shall determine each month the actual recovery

by Transporter of the Electric Power Cost by multiplying

the Electric Power Cost Recovery Surcharge by the Actual

Volumes.

 

(c) Each month, Transporter shall determine the difference,

positive or negative, between the costs computed in

accordance with Section 32B.5(a) and 32B.5(b) and such

difference shall be recorded each month in a Subaccount of

Account No. 186 of the Uniform System of Accounts which

Transporter shall designate as a Deferred Electric Power

Cost Account.