Guardian Pipeline, L.L.C.
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 12/01/2002, Docket: RP02-534-000, Status: Effective
Original Sheet No. 121 Original Sheet No. 121 : Superseded
GENERAL TERMS AND CONDITIONS
(Continued)
5. MEASUREMENT & MEASUREMENT EQUIPMENT (Continued)
(c) Any errors or discrepancies found during testing
shall be corrected immediately whenever possible
or as soon thereafter as procurement of repair
parts, materials, and tools can be arranged.
5.7 Measurement Equipment Inaccuracy and Failure
The quantity of Natural Gas received and delivered by
Transporter and delivered to Shipper or for Shipper's
account hereunder during periods when the measurement
equipment is out of service or registering
inaccurately shall be estimated as follows:
(a) If, upon test, any measurement equipment, the
readings of which are used in the registration,
integration, or computation of quantities of
Natural Gas hereunder, is found to be in error
to the extent that it introduces not more than
one percent (1%) measurement error, in the
individual measurement equipment affected,
previous records of such equipment shall be
considered accurate.
(b) If, upon test, any such above measurement
equipment is found to be in error, to the extent
that it causes the registered or computed
quantities of the instrument(s) so affected to
be in error, by an amount exceeding one percent
(1%) such instrument(s) affected shall be
corrected to zero (0) error for any part of the
period since the last test in which such error
is known to have existed or which may be agreed
upon by representatives of Transporter and
Connecting Party. In case the period of such
error is not known definitely or agreed upon,
such correction shall be for a period of
one-half («) of the elapsed time since the date
of the last test, but not exceeding a correction
period of thirty (30) days.