Southeast Supply Header, LLC
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 09/04/2008, Docket: CP07-44-005, Status: Effective
Original Sheet No. 214 Original Sheet No. 214
GENERAL TERMS AND CONDITIONS
(CONTINUED)
2. MEASUREMENT AND MEASUREMENT EQUIPMENT (continued)
2.2 (a) The volume of Gas delivered at each Receipt Point and
Delivery Point shall be calculated by means of an
electronic flow computer located at each Receipt Point
or each Delivery Point, in the following manner:
(1) The volume of Gas delivered through an orifice meter
shall be computed in accordance with AGA Report No.
3, properly using all factors set forth therein.
(2) The volume of Gas delivered through a turbine meter
shall be computed in accordance with AGA Report No.
7, properly using all factors set forth therein.
(3) The volume of Gas delivered through an ultrasonic
meter shall be computed in accordance with AGA Report
No. 9, properly using all factors set forth therein.
(4) The volume of Gas delivered through a positive
displacement meter shall be computed by properly
applying, to the volume delivered at flowing Gas
pressures and temperatures, correction factors for
(i) absolute static pressure, (ii) flowing Gas
temperature, and (iii) compressibility ratio.
(b) The volume of Gas delivered shall be computed using the
standards and factors determined as follows:
(1) The unit of volume for the purpose of measurement
shall be one thousand cubic feet of Gas at a
temperature of sixty (60) degrees Fahrenheit and a
pressure of 14.73 pounds per square inch absolute.
For the purpose of pricing hereunder, the Dekatherm
equivalent of such unit of volume shall be determined
by multiplying each such unit of volume by the total
heating value per cubic foot of the Gas Delivered
Hereunder (adjusted to a common temperature and
pressure base) and by dividing the result by one