Florida Gas Transmission Company, LLC

Fourth Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 09/01/2006, Docket: RP06-463-000, Status: Effective

Original Sheet No. 208 Original Sheet No. 208 : Effective

 

GENERAL TERMS AND CONDITIONS

(continued)

 

2. To the extent Shippers conform with requirements hereof, the

gas shall have a total heating value of not less than one

thousand (1000) Btu per cubic foot of dry gas, and be

reasonably free of moisture, objectionable liquids and

solids so as to be merchantable upon delivery to Shipper,

and shall contain not more than two hundred (200) grains of

total sulphur, nor more than fifteen (15) grains of hydrogen

sulphide, per MCF. The gas may contain an odorant at the

point of delivery, but it is the responsibility of the

customer to monitor and maintain any required odorant levels

after the point of delivery.

 

3. Transporter may utilize gas from any standby equipment to

effectuate deliveries provided the gas shall be reasonably

equivalent to the gas delivered to Transporter by or for the

account of Shipper hereunder, and adopted for use by

Shipper's consumers without the necessity of making

adjustments to fuel-burning equipment.

 

3. PRESSURE

 

Gas shall be delivered at such uniform pressure as Shipper may

reasonably require, and as Transporter may agree to deliver, up to but

not exceeding two hundred fifty (250) pounds per square inch gauge at

the point of delivery or such other pressure as may be provided for in a

contract between Transporter and Shipper; provided however, Transporter

may grant from time to time an increase in pressure above two hundred

fifty (250) pounds per square inch gauge if Transporter determines in

its sole discretion that such increase would not adversely affect the

ability of Transporter to deliver gas to its firm rate schedule

customers. To the extent Shipper desires to increase to the revised

pressure standard, Shipper shall pay for any meter facilities or other

facility additions or upgrades required to deliver gas at higher

pressures. Shipper shall be required to install, operate and maintain

such regulating devices as may be necessary to regulate the pressure

after delivery to Shipper.