Destin Pipeline Company, L.L.C.
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 09/01/1998, Docket: CP96-655-003, Status: Effective
Original Sheet No. 58 Original Sheet No. 58 : Effective
GENERAL TERMS AND CONDITIONS
(Continued)
Section 5.3(c) (continued)
COMPANY's meters only, except as otherwise specifically
provided to the contrary in this Section. COMPANY shall have
access to such check measuring equipment at all reasonable
hours, but the operation of such check measuring equipment
shall be done only by SHIPPER.
(d) Measurement Inaccuracies Requiring Shipper Action. If
COMPANY determines that the meter station volume readings are
inaccurate due to factors beyond the scope of routine
operations and maintenance, including, but not limited to,
pulsation, COMPANY shall notify SHIPPER of such inaccuracies.
Within thirty (30) days of receipt of such notice from
COMPANY, SHIPPER shall at its own expense make or cause to be
made such modifications to its facilities as are necessary to
remove such inaccuracies. If COMPANY determines that
SHIPPER's modifications have not corrected the measurement
inaccuracies, upon 30 days notice in writing to SHIPPER of
the continuing measurement inaccuracies, COMPANY may suspend
operation of the meter station and refuse to receive gas into
COMPANY's pipeline until the measurement inaccuracies are
corrected or COMPANY may install pulsation dampening
equipment at SHIPPER's sole cost and expense.
(e) Prior Period Adjustments. The deadline for closing
measurement data shall be no later than 5 business days after
the month of flow. Any measurement data or corrections
received by COMPANY (including corrections to allocations)
after it has closed the previous month of flow shall be
handled as a prior period adjustment. COMPANY shall process
late measurement data or corrections of measurement errors
under Section 5.3 (a) or (b) as soon as practicable but no
later than 6 months after the applicable month of flow in