Dauphin Island Gathering Partners
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 01/10/1999, Docket: RP99-181-000, Status: Effective
First Revised Sheet No. 117 First Revised Sheet No. 117 : Effective
Superseding: Original Sheet No. 117
recording devices in which case the temperature at
which gas was measured for the period of such record
shall be the arithmetic average of the record during
the period of time during which gas was flowing, or
(2) used for on-site flow computations in electronic
flow computers in which case the instantaneous
measurement of temperature will be used in such
computations.
(d) Each month a specific gravity correction shall be
applied to measured volumes based upon the specific
gravity determined or sampled during that month.
The specific gravity to be used for such correction
shall be determined at an appropriate location from
a continuous sampling device, by a gravitometer,
chromatograph or other device of standard
manufacture and shall be either (1) recorded using
digital recorders or other mutually agreeable
recording device in which case an arithmetic average
(to be determined during the period of time during
which flow was occurring at the location of the
specific gravity recorder) of such record shall be
the specific gravity of the gas being measured, or
(2) used for flow computations in electronic flow
computers in which case the value of the specific
gravity being measured will be used as appropriate
in such computations. If a continuous specific
gravity measuring device is not installed or
available at an appropriate location, then specific
gravity shall be determined monthly from a
continuous sampling device or by a mutually
agreeable method.
(e) Each month a gross heating value correction shall be
applied to measured volumes based upon the gross
heating value determined or sampled during that
month. The gross heating value shall be determined
at an appropriate location from a continuous
sampling device, by a calorimeter, chromatograph or
other device of standard manufacture and shall be
either (1) recorded using digital recorders or other
mutually agreeable recording device in which case
arithmetic average (to be determined during the
period of time during which flow was occurring at
the location of the gross heating value recorder) of
such record shall be the gross heating value of the
gas being measured, or (2) entered as an input to
electronic flow computers in which case the gross
heating value being measured will be used in the
computation of the Btu content of the gas. If a
gross heating value measuring device is not
installed or available at an appropriate location,
then the gross heating value shall be determined
monthly from a continuous sampling device or by a
mutually agreeable method.