Dauphin Island Gathering Partners
First Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 03/16/1999, Docket: CP98- 6-003, Status: Effective
Original Sheet No. 128 Original Sheet No. 128 : Effective
(d) Each month a specific gravity correction shall be applied to measured volumes
based upon the specific gravity determined or sampled during that month. The
specific gravity to be used for such correction shall be determined at an
appropriate location from a continuous sampling device, by a gravitometer,
chromatograph or other device of standard manufacture and shall be either (1)
recorded using digital recorders or other mutually agreeable recording device in
which case an arithmetic average (to be determined during the period of time
during which flow was occurring at the location of the specific gravity recorder)
of such record shall be the specific gravity of the gas being measured, or (2)
used for flow computations in electronic flow computers in which case the value
of the specific gravity being measured will be used as appropriate in such
computations. If a continuous specific gravity measuring device is not installed
or available at an appropriate location, then specific gravity shall be determined
monthly from a continuous sampling device or by a mutually agreeable method.
(e) Each month a gross heating value correction shall be applied to measured
volumes based upon the gross heating value determined or sampled during that
month. The gross heating value shall be determined at an appropriate location
from a continuous sampling device, by a calorimeter, chromatograph or other
device of standard manufacture and shall be either (1) recorded using digital
recorders or other mutually agreeable recording device in which case arithmetic
average (to be determined during the period of time during which flow was
occurring at the location of the gross heating value recorder) of such record shall
be the gross heating value of the gas being measured, or (2) entered as an input
to electronic flow computers in which case the gross heating value being
measured will be used in the computation of the Btu content of the gas. If a
gross heating value measuring device is not installed or available at an
appropriate location, then the gross heating value shall be determined monthly
from a continuous sampling device or by a mutually agreeable method.
DAUPHIN ISLAND GATHERING PARTNERS
FERC GAS TARIFF
First Revised Volume No. 1 Original Sheet No. 33
Issued by: W. J. White, Director Effective: March 16, 1999
Issued on: March 25, 1999