Dauphin Island Gathering Partners
First Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 03/16/1999, Docket: CP98- 6-003, Status: Effective
Origianl Sheet No. 122 Origianl Sheet No. 122 : Effective
(i) Impurities. The gas shall be free from polychlorinated biphenyls and
commercially free (at prevailing pressure and temperature in Transporter's MP
Facility) from dust, gums, sand, oil or other foreign substances which may be
injurious to Transporter's MP Facility or other facilities.
(j) Total Heating Value. No gas received hereunder at any Receipt Point(s) on
Transporter's MP Facility shall have a total heating value (1) less than 1000 Btu
per cubic foot (as determined in accordance with Section 3 of these General
Terms and Conditions), or (2) in excess of that permitted by the most strict
quality specification for maximum total heating value of the downstream
pipelines at all Delivery Points on Transporter's MP Facility; provided,
Transporter shall accept receipt of gas not meeting such maximum heating value
specification if Shipper processes such gas or has it processed to comply with
such specification prior to the delivery of such gas to the downstream pipeline(s)
at the Delivery Point(s).
Notwithstanding 2.1(a) through (i) above, inclusive, all gas delivered or caused to be
delivered by Shipper to Transporter at the Receipt Point(s) shall conform to the most
strict quality specification of the downstream pipelines at the Delivery Points for each
individual quality specification, any of which may be waived by Transporter in its
discretion on a nondiscriminatory basis.
2.2 Specifications:
All gas delivered or caused to be delivered by Shipper to Transporter at the Receipt
Point(s) on Transporter's DI Facility shall conform to the following quality
specifications, any of which may be waived by Transporter in its discretion on a
nondiscriminatory basis:
(a) Oxygen. The gas shall not contain more than two-tenths of one percent (0.2%)
by volume of oxygen, and Shipper shall make every reasonable effort to keep
the gas free of oxygen.
(b) Liquids and Water Vapor. The gas shall be free of water and hydrocarbons in
liquid form at the temperature and pressure at which the gas is received at the
Receipt Point(s), and shall not contain in excess of seven (7) pounds of water
vapor per million cubic feet.