2. QUALITY
The quality specifications herein shall apply to all gas delivered to Transporter by Shipper under
all Rate Schedules.
2.1 Specifications for Transporter's MP Facility:
All gas delivered or caused to be delivered by Shipper to Transporter at the Receipt
Point(s) on Transporter's MP Facility shall conform to the following quality
specifications, any of which may be waived by Transporter in its discretion on a
nondiscriminatory basis:
(a) Oxygen. The gas shall not contain more than two-tenths of one percent (0.2%)
by volume of oxygen, and Shipper shall make every reasonable effort to keep
the gas free of oxygen.
(b) Liquids and Water Vapor. The gas shall be free of water and hydrocarbons in
liquid form at the temperature and pressure at which the gas is received at the
Receipt Point(s), and shall not contain in excess of seven (7) pounds of water
vapor per million cubic feet.
(c) Hydrogen Sulfide. The gas shall not contain more than 0.25 of a grain of
hydrogen sulfide per hundred cubic feet.
(d) Temperature. The gas shall have a temperature of not more than one hundred
twenty degrees (120) Fahrenheit and not less than forty (40) degrees Fahrenheit.
(e) Sulfur. The gas shall not contain more than five (5) grains of total sulfur per
hundred cubic feet.
(f) Carbon Dioxide. The gas shall not contain more than one and one-half percent
(1«%) by volume of carbon dioxide.
(g) Nitrogen. The gas shall not contain more than two percent (2%) by volume of
nitrogen.
(h) Non-Hydrocarbon Gases. The gas shall not contain more than four percent (4%)
by volume of non-hydrocarbon gases, including the above listed non-
hydrocarbon gases.