14.6 METERING FACILITIES - Upon agreement with Transporter,
either Transporter or an interconnecting Operator may
install, own, maintain and operate metering facilities
properly equipped with orifice meters, electronic flow
computers, and other necessary measuring equipment
required to measure quantities of Gas received into or
delivered from Transporter's System. Such metering
facilities will be located at or near the Receipt or
Delivery Point(s).
14.7 CHECK METERS - Either Transporter or the interconnecting
Operator may, at its option and expense, install and
operate check meter(s) to check the other party's meters.
14.8 ACCESS TO METERING FACILITIES - Either Transporter or the
interconnecting Operator shall have access at all
reasonable times to the other party's metering and
regulating facilities for inspection and checking, but
the reading, calibration and adjustment thereof shall be
done only by the Operator of such metering and regulating
facilities.
14.9 CALIBRATION AND TESTING - At least once each Month,
either Transporter or the interconnecting Operator will
calibrate its meters and measuring equipment and if so
requested, in the presence of representatives of the
other party, and the parties shall jointly observe any
adjustments that are made to the meters or measuring
equipment should adjustments be necessary. Likewise, any
calibration and adjustment of the other party's check
meters will be jointly observed by representatives of
both parties. Each party shall give to the other party
notice of the time of all tests of meters at least ten
(10) Days in advance of the test so that the other party
may conveniently have its representatives present. If
the required notice of a meter test has been given and
the party receiving such notice is not present or
represented at the time set, the other party may proceed
with the test and any necessary adjustment.