GSS-E RATE SCHEDULE
General Storage Service - Expansion
7.2 Deliveries Under FT or FTNN Agreement. As to any quantities injected
by Pipeline for Customer's account which were delivered to Pipeline
under Customer's FT or FTNN Service Agreement, payment of the demand
and injection charges under this Rate Schedule, or, if applicable,
such other charges mutually agreed upon by Pipeline and Customer, shall
be deemed to satisfy Customer's obligation to pay the usage charge
specified in Section 5.1.B., and the Transportation Service Fuel
Retention Percentage specified in Section 5.2, of Rate Schedule FT or
FTNN (excluding any applicable Sheet No. 37 provision).
7.3 General Procedure. For any Day when Customer desires Pipeline to
store gas for its account under this Rate Schedule, it shall nominate
to Pipeline in accordance with the General Terms and Conditions of this
Tariff, specifying the quantity of gas it desires to have injected into
storage on such Day. When Customer's nominations are confirmed and
scheduled as required by this Tariff, Pipeline shall inject into
storage for Customer's account on such Day, the quantity of gas so
nominated, subject to the limitations set forth below in this Section
7.
7.4 Summer Period Injections.
A. Daily Injection Entitlement. Unless provided otherwise in
Customer's Service Agreement, during any Summer Period, the
quantity of gas which Customer shall be entitled to tender to
Pipeline for injection into storage on any one Day is one-one
fiftieth (1/150th) of Customer's Storage Capacity whenever
Customer's Storage Gas Balance is less than or equal to one half
of Customer's Storage Capacity, and one-one eightieth (1/180th)
of Customer's Storage Capacity whenever Customer's Storage Gas
Balance is greater than one half of Customer's Storage Capacity.
These limitations upon daily injection entitlement are subject to
the tolerance levels set forth in Section 35.3.A of the General
Terms and Conditions.
B. Maximum Daily Injection Quantity. The maximum daily injection
quantity for Customer shall be the sum of Customer's daily
injection entitlement as set forth in Section 7.4.A. above, plus
any additional injection quantities that Pipeline has agreed to