Dominion Transmission, Inc.

Third Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 09/23/2000, Docket: RP00-555-000, Status: Effective

Original Sheet No. 358 Original Sheet No. 358 : Effective

 

 

GSS RATE SCHEDULE

General Storage Service , Section 7(c)

 

8.5 Minimum Storage Gas Balance and Additional Reduction in

Customer's Daily Entitlement.

 

A. Each Customer must maintain a Storage Gas Balance

equal to or greater than the following percentages of

Storage Capacity on each Day during the following

Winter Period months:

December 35%

January 35%

February 15%

 

B. If Customer does not maintain the required Storage Gas

Balance then, commencing on such Day and continuing

until Customer's Storage Gas Balance is at the level

required under Section 8.5.A., Pipeline's obligation

to make deliveries to Customer shall be reduced by 10

percent of the lesser of (1) Customer's Storage Demand

or (2) Pipeline's obligation to deliver as established

pursuant to Section 8.4 above.

 

8.6 Limitations on Withdrawals. During any calendar month,

Pipeline shall not be obligated to deliver a daily average

in excess of the following: (1) more than 70 percent of the

Customer's daily entitlement described under Section 8.4,

if Customer's Storage Demand is equal to or greater than

one-sixtieth (1/60th) of Customer's Storage Capacity, or

(2) more than 87.5 percent of the Customer's daily

entitlement described under Section 8.4, if Customer's

Storage Demand is less than one-sixtieth (1/60th) of

Customer's Storage Capacity. Pipeline may issue an

operational flow order to limit storage withdrawals, in

accordance with Section 11B of the General Terms and

Conditions of this Tariff. The limitations under this

Section 8.6 shall not apply to transfers of storage

inventory in accordance with Section 34 of the General

Terms and Conditions.

 

8.7 Minimum Turnover. By April 15 of any year, Customer's total

withdrawals from storage since the beginning of the

preceding, just completed, Winter Period must be equal to

or greater than the amount by which Customer's Storage Gas

Balance as of November 1 of the preceding calendar year

exceeds 35 percent of Customer's Storage Capacity. If

Customer has failed to withdraw such quantities, then

Customer will be subject to the penalties of Section 35.3.D