Columbia Gulf Transmission Company
Second Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 07/01/1996, Docket: RP96-261-000, Status: Effective
First Revised Sheet No. 238 First Revised Sheet No. 238 : Effective
Superseding: Original Sheet No. 238
GENERAL TERMS AND CONDITIONS (Continued)
26. MEASUREMENT
26.1 Measuring station(s) and equipment shall be installed in accordance with Transporter's
specifications, by which the volumes of gas delivered hereunder shall be determined.
26.2 Orifice Meters - When orifice meters are used, the gas delivered shall be measured with
meters designed, constructed and installed, and whose computations of volumes are made, in accordance
with the provision of AGA Measurement Committee Report No. 3 of the American Gas Association as
reprinted and revised September 1985, (AGA Report No. 3), with any subsequent amendments or revisions
which may be mutually acceptable to the parties.
26.3 Positive or Turbine Meters - When positive meters are used, the gas delivered shall be
measured with meters designed, constructed and installed, and whose computations of volumes are made,
in accordance with the provisions of AGA Measurement Report No. 6 (AGA Report No. 6). When turbine
meters are used, the gas delivered shall be measured with meters designed, constructed and installed,
and whose computations of volumes are made, in accordance with the provisions of AGA Measurement
Committee Report No. 7 (AGA Report No. 7). Subsequent amendments or revisions of either AGA Report
No. 6 or 7 which may be mutually acceptable to the parties may be utilized.
26.4 The unit of volume for purposes of measurement of volumes hereunder shall be a "cubic foot
of gas" as defined in Section 1.4 of these General Terms and Conditions.