Colorado Interstate Gas Company
First Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 06/01/2010, Docket: RP10-689-000, Status: Effective
Eighth Revised Sheet No. 245 Eighth Revised Sheet No. 245
Superseding: Seventh Revised Sheet No. 245
GENERAL TERMS AND CONDITIONS
(Continued)
3.2 (Continued)
(h) Transporter may accept Gas with a Gross Heating Value of not
less than 950 Btus per cubic foot at a pressure of 14.73
p.s.i.a. and a temperature of 60 degrees Fahrenheit into the
Powder River Lateral, provided the Gas is Delivered to a
Powder River Lateral location or Transporter is able to blend
the gas to meet downstream gas quality delivery requirements
at non-Powder River Lateral delivery points.
(i) In addition, Transporter may accept any Gas that does not meet
the specifications set forth in Section 3.1 on a short term
basis for operational reasons which may include plant start-
ups, plant upsets, or line freeze-offs.