Colorado Interstate Gas Company
First Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 06/01/2010, Docket: RP10-689-000, Status: Effective
Eleventh Revised Sheet No. 242 Eleventh Revised Sheet No. 242
Superseding: Tenth Revised Sheet No. 242
GENERAL TERMS AND CONDITIONS
(Continued)
3. QUALITY
3.1 Specifications. Unless otherwise agreed pursuant to Sections 3.2 and
3.3 below, Shipper warrants that Gas Tendered hereunder at each
Point of Receipt and Point of Delivery will comply with the
following quality specifications:
(a) At a pressure of 14.73 p.s.i.a. and a temperature of 60 degrees
Fahrenheit, such Gas shall not contain more than:
(i) .25 grain of hydrogen sulphide per 100 cubic feet,
(ii) 5 grains of total sulphur per 100 cubic feet,
(iii) 10 parts per million (0.001 percent) by volume of
oxygen; however, this oxygen quality specification shall
not apply at Point(s) of Delivery on the Valley Line and
its supporting blending operations (see Section 3.8
below for oxygen specifications applicable to the Valley
Line and its supporting blending operations,)
(iv) 3.0 percent by volume of carbon dioxide,
(v) 7 pounds of water vapor per million cubic feet at
Point(s) of Receipt and Point(s) of Delivery within the
states of Kansas, Oklahoma, and Texas and 5 pounds of
water vapor per million cubic feet in all other states.
(b) Shipper warrants that all Gas Tendered will be commercial in
quality and shall be free from any foreign material such as
solids, lubricating oils, sand, dirt, dust, gums, crude oil,
water or hydrocarbons in the liquid phase, metal particles, and
other objectionable substances, including, but not limited to,
polychlorinated biphenyls, which may be injurious to pipelines,
people, property, or the environment which may interfere with
its Transportation or makes the Gas unmarketable or
unacceptable for Delivery from Transporter's transmission
system.
(c) Shipper warrants that all Gas Tendered will have a Gross
Heating Value of not more than 1,235 Btu's nor less than 968
Btu's per cubic foot at a pressure of 14.73 p.s.i.a. and a
temperature of 60 degrees Fahrenheit.
(d) Shipper warrants that the temperature of the Gas Tendered will
not exceed 120 degrees Fahrenheit; provided, however, if
Transporter is required to dehydrate the Gas at the Point(s) of