15. Measurements
(a) Measurement Unit
The measurement unit of the natural gas delivered by
Seller shall be one (1) Dekatherm (dt).
(b) Determination of Volume and Heating Valve
The volume and the heating value of the natural gas
delivered by Seller shall be determined as follows:
(1) The unit of volume for the purpose of measurement
shall be one (1) Mcf of gas at a temperature of
sixty (60) degrees Fahrenheit and at an absolute
pressure of fourteen and seventy-three hundredths
(14.73) pounds per square inch.
(2) The pressure and temperature of the gas passing
through the meters shall be determined by the use of
electronic measurement equipment or other recording
device. The instantaneous measurements from the
electronic measurement equipment or the average of
the pressure and temperature recorded each Day shall
be used in computing gas volumes. For both
reporting and calculation purposes pressure base
conversion factors shall be reported to not less
than six (6) decimal places.
(3) The specific gravity of the gas delivered by Seller
on any Day shall be fixed at a value, which is a
representative value of that which is reported to
Seller by the interconnecting upstream pipeline(s).
(4) The deviation of the natural gas from Boyle's and
Charles' Law shall be that determined in accordance
with, but not limited to, the published
recommendations of the American Gas Association and
the American National Standards Institute as
Seller deems to be in accordance with accepted
industry practice. The amount of nitrogen and
carbon dioxide contained in gas for the purpose of
determining the deviation factors shall be derived
from that which is reported to Seller by the
interconnecting upstream pipeline(s).