Clear Creek Storage Company, LLC

Original Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 06/01/2000, Docket: CP98-256-002, Status: Effective

Original Sheet No. 65 Original Sheet No. 65 : Effective

 

GENERAL TERMS AND CONDITIONS

(Continued)

 

(1) At intervals of not more than six Months, by

means of an instrument of standard manufacture accepted in

the industry for this purpose using a sample of Gas from the

Gas stream at the point of receipt and delivery.

 

(2) By means of an instrument of standard

manufacture accepted in the industry for this purpose

installed at a point to measure the specific gravity of the

Gas stream from which Gas is being delivered at the point of

receipt and delivery.

 

14.5 The compressibility ratio factor(s) used in

computing the volume of Gas delivered through a turbine

meter or a positive displacement meter shall be determined

by the equation s = (Fpv)2, in which "Fpv" is the

supercompressibility factor determined as described in

Paragraph 14.3(4) above.

 

14.6 In determining the flowing temperature factor,

supercompressibility factor and compressibility ratio

factor(s) for use in computing the volume of Gas delivered

through a meter, the flowing Gas temperature for only the

period(s) of time that Gas was flowing through the meter

shall be used.

 

14.7 All flow, measuring, testing and related equipment

shall be of standard manufacture and type approved by Clear

Creek. If applicable, Clear Creek or Customer may install

check measuring equipment, provided that installation of

such equipment does not interfere with the operations of the

Operator. Clear Creek, or Customer, in the presence of the

other party, shall have access to measuring equipment at all

reasonable times, but the reading, calibrating and adjusting

thereof and the changing of charts, if any, shall be done by

the Operator. Clear Creek or Customer shall have the right

to be present at the time of the installing, reading,

cleaning, changing, repairing, inspecting, testing,

calibrating or adjusting done by the Operator of the

measuring equipment. The records from the measuring

equipment shall remain the property of the Operator, but

upon request, the other party may request records, including

charts, if any, together with calculations therefrom for

inspection, subject to return within 30 Days after receipt

thereof.

 

Reasonable care shall be exercised in the installation,

maintenance and operation of the measuring equipment to