Central New York Oil And Gas Company, LLC
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 12/01/2001, Docket: CP00- 61-001, Status: Effective
Original Sheet No. 92 Original Sheet No. 92 : Effective
GENERAL TERMS AND CONDITIONS (continued)
(c) other method mutually agreed upon by both
parties.
For the purpose of calculating injections and
withdrawals, the heat content of the Gas so
determined at each such point shall be deemed to
remain constant at such point until the next
determination. The unit of quantity for the
purpose of determining total heating value shall
be one (1) cubic foot of anhydrous Gas at a
temperature of sixty degrees (60) Fahrenheit and
an absolute pressure of 14.73 psia, dry.
7.2 Freedom from Objectionable Matter. The Gas
injected and withdrawn hereunder:
(a) shall be commercially free, at
prevailing pressure and temperature in
Seller's equipment and facilities, from
objectionable odors, dust or other solid or
liquid matter which might interfere with its
merchantability or cause injury to or
interference with proper operation of the
lines, regulators, meters and other equipment
and facilities of Seller.
(b) shall not contain more than one
quarter (.25) grain of hydrogen sulfide per
one hundred (100) cubic feet of Gas, as
determined by methods prescribed in Standards
of Gas Service, Circular of the National
Bureau of Standards, No. 405, page 134 (1934
edition), and shall be considered free from
hydrogen sulfide (H2S) if a strip of white
filter paper, moistened with a solution
containing five percent (5%) by weight of
lead acetate, is not distinctly darker than a
second paper freshly moistened with the same
solution, after the first paper has been
exposed to the Gas for one and one-half (1-
1/2) minutes in an apparatus of approved
form, through which the Gas is flowing at the
rate of approximately five (5) cubic feet per
hour, the Gas from the jet not impinging
directly upon the test paper; or the H2S
content may be determined by an instrument of
approved type and by approved methods
agreeable to the parties;
(c) shall not contain more than twenty
(20) grains of total sulfur (including the
sulfur in any hydrogen sulfide and
mercaptans) per one hundred (100) cubic feet
of Gas;
(d) shall not at any time have an oxygen content
in excess of two-tenths of one percent (0.20%) by volume and
the parties hereto shall make every reasonable effort to
keep the Gas free of oxygen;