Cheniere Creole Trail Pipeline, L.P.

Original Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 04/28/2008, Docket: RP08-137-000, Status: Effective

Original Sheet No. 118 Original Sheet No. 118 : Pending

 

 

GENERAL TERMS AND CONDITIONS

(Continued)

 

G. Correction of Meter Errors. If, upon test, any measuring equipment is

found to be not more than one (1) percent fast or slow, except chromatographs,

recording calorimeters or gravitometers whose allowable margin of error shall

be not more than one half of one percent (0.5%) fast or slow, previous

recordings of such equipment shall be considered correct in computing

deliveries of gas hereunder; but such equipment shall be adjusted at once to

record accurately. If, upon test, any measuring equipment shall be found to be

inaccurate by an amount exceeding one (1) percent, at a recording

corresponding to the average hourly rate of flow for the period since the last

preceding test, or with respect to chromatographs, recording calorimeters or

gravitometers greater than one half of one percent (0.5%), then any previous

recordings of such equipment shall be corrected to zero error for any period

which is known definitely or agreed upon, but in case the period is not known

definitely or agreed upon such corrections shall be for a period extending

over one-half of the time elapsed since the date of the last test of such

equipment, not exceeding a correction period of thirty (30) days.

 

H. Turbine Meters. When turbine meters are used, the equipment will be

installed and operated in accordance with the specifications of American Gas

Association, Gas Measurement Committee Report No. 7 dated 1981 as amended from

time to time.

 

I. Orifice Meters. When orifice meters are used the equipment will be

installed and operated in accordance with the specifications of the most

current edition of the American Gas Association, Gas Measurement Committee

Report No. 3 as amended from time to time.

 

J. Ultrasonic Meters. When ultrasonic meters are used the equipment will be

installed and operated in accordance with the specifications of the most

current edition of the American Gas Association, Gas Measurement Committee

Report No. 9, as amended from time to time.

 

K. Preservation of Records. Both Transporter and Shipper shall preserve all

test data, charts and other similar records for such period of time as the

Federal Energy Regulatory Commission shall specify from time to time in its

Schedule of Records and Periods of Retention.