4.4 Positive Displacement Meters - Positive Displacement
Meters installed in such measuring stations shall be constructed and
operated in accordance with the provisions of AGA Measurement
Committee Report No. 6 (AGA Report No. 6) dated January 1971, and
any subsequent amendment or revisions thereof.
4.5 Turbine Meters - Turbine Meters installed in such
measuring stations shall be constructed and operated in accordance
with the provisions of AGA Measurement Committee Report No. 7 (AGA
Report No. 7), First Revision, dated November 1984, and any
subsequent modifications and amendments thereof.
4.6 Electronics - When and where electronic equipment and
flow computers are used, the gas may have its volume, mass and/or
energy content determined and computed in accordance with the
applicable AGA Standards including, but not limited to, AGA Report
No(s). 3, 5, 6, and 7 and any subsequent modifications and
amendments thereof. The parties agree to accept the use of
electronic devices and calculations in lieu of mechanical devices
and chart integration.
4.7 Notice - Caprock shall give reasonable notice to Shipper
in order that Shipper may have representatives present to observe
any installing, reading, cleaning, changing, repairing, inspecting,
testing, calibrating, or adjusting of Caprock's measuring equipment
used in measuring or checking the measurement of receipts or
deliveries of gas under the Agreement. The official charts
(recordings) from such measuring equipment shall remain the property
of Caprock, but upon request, Caprock will submit its records and
charts, together with calculations therefrom, to Shipper for
inspection and verification, subject to return to Caprock within
thirty (30) days after receipt thereof.
4.8 Testing and Calibration
(A) Caprock shall verify the accuracy, adjust and
calibrate all recording devices used in the measurement of the
receipt of gas on at least a quarterly basis. Caprock shall
not be required to, but may elect to, adjust or calibrate such
equipment more frequently than specified above, unless Shipper
desires a special test be performed as described in Section
4.9 below.
(B) If, during any test of the measuring equipment, an
adjustment or calibration error is found which results in an
incremental adjustment to the calculated hourly flow rate
through each meter run in excess of two percent (2%) of the
correct flow rate (whether positive or negative and using the
correct flow rate as the percent error equation denominator),
then any previous recording of such equipment shall be
corrected to zero (0) error for any period which the error
existed (and which is either known definitely or agreed to by
both parties) and the total flow for the period redetermined
in accordance with the provisions of Section 4.10 below. If
the period of error cannot be determined or agreed upon
between the