(a) Be commercially free from objectionable odors, dirt,

dust, iron particles, gums, gum-forming constituents, gasoline,

PCBs, and other solid and/or liquid matter, including but not

limited to water, Gas treating chemicals and well completion fluids

and debris, which may become separated from the Gas during the

transportation thereof.

 

(b) Contain not more than one fourth (1/4) of one grain

of hydrogen sulfide per one hundred (100) cubic feet, as determined

by the cadmium sulfate quantitative test, nor more than twenty (20)

grains of total sulfur per one hundred (100) cubic feet.

 

(c) The Gas delivered hereunder shall not contain more

than two-tenths of one percent (0.2%) by volume of oxygen, shall not

contain more than three percent (3%) by volume of carbon dioxide,

shall not contain more than three (3%) by volume of nitrogen, and

shall not contain a combined total of carbon dioxide and nitrogen

components of more than four (4%) by volume.

 

(d) Have a heating value of not less than nine hundred

and sixty-seven (967) Btus per cubic feet and not more than eleven

hundred (1100) Btus per cubic feet.

 

(e) Have a temperature of not more than 120 degrees

Fahrenheit (120 degrees F), nor less than forty degrees Fahrenheit

(40 degrees F).

 

(f) Have been dehydrated by the tendering party, by any

method other than the use of a calcium chloride as desiccant, for

removal of entrained water in excess of four (4) pounds of water per

million (1,000,000) cubic feet of Gas as determined by dew-point

apparatus approved by the Bureau of Mines or such other apparatus as

may be mutually agreed upon.

 

10.2 Rejection of Gas. Either party shall be entitled to

reject any Gas tendered to it by the other party which does not meet

the minimum specifications of Section 10.1 hereunder. Acceptance of

such Gas does not constitute any waiver of BLUEWATER's right to

refuse to accept similarly nonconforming Gas.

 

11. PRESSURE AND INJECTION/WITHDRAWAL RATES

 

11.1 Delivery Pressures. BLUEWATER shall deliver Gas to

Customer at pressures sufficient to enter the pipeline facilities at

the Point(s) of Delivery against the operating pressures maintained

by Transporter(s) from time to time. BLUEWATER shall not be

required to deliver Gas at pressures in excess of those required by

Transporter(s) or in excess of Transporter(s) maximum allowable

operating pressure (MAOP), not to exceed 960 psig. Customer shall

deliver or cause to be delivered to BLUEWATER all Gas for wheeling,

parking or injection at the Point(s) of Receipt at pressures not

less than 700 psig and not in excess of the MAOP of BLUEWATER's

facilities at the Point(s) of Receipt. BLUEWATER shall be

responsible for maintaining facilities at such Point(s) of Receipt

to permit Customer to deliver Gas to BLUEWATER at such allowed

pressures.