Bluewater Gas Storage, LLC
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 12/01/2006, Docket: CP06-351-001, Status: Effective
Original Sheet No. 140 Original Sheet No. 140 : Effective
GENERAL TERMS AND CONDITIONS
(Continued)
(a) Be commercially free from objectionable odors, dirt,
dust, iron particles, gums, gum-forming constituents, gasoline,
PCBs, and other solid and/or liquid matter, including but not
limited to water, Gas treating chemicals and well completion fluids
and debris, which may become separated from the Gas during the
transportation thereof.
(b) Contain not more than one fourth (1/4) of one grain
of hydrogen sulfide per one hundred (100) cubic feet, as determined
by the cadmium sulfate quantitative test, nor more than twenty (20)
grains of total sulfur per one hundred (100) cubic feet.
(c) The Gas delivered hereunder shall not contain more
than two-tenths of one percent (0.2%) by volume of oxygen, shall not
contain more than three percent (3%) by volume of carbon dioxide,
shall not contain more than three (3%) by volume of nitrogen, and
shall not contain a combined total of carbon dioxide and nitrogen
components of more than four (4%) by volume.
(d) Have a heating value of not less than nine hundred
and sixty-seven (967) Btus per cubic feet and not more than eleven
hundred (1100) Btus per cubic feet.
(e) Have a temperature of not more than 120 degrees
Fahrenheit (120 degrees F), nor less than forty degrees Fahrenheit
(40 degrees F).
(f) Have been dehydrated by the tendering party, by any
method other than the use of a calcium chloride as desiccant, for
removal of entrained water in excess of four (4) pounds of water per
million (1,000,000) cubic feet of Gas as determined by dew-point
apparatus approved by the Bureau of Mines or such other apparatus as
may be mutually agreed upon.
10.2 Rejection of Gas. Either party shall be entitled to
reject any Gas tendered to it by the other party which does not meet
the minimum specifications of Section 10.1 hereunder. Acceptance of
such Gas does not constitute any waiver of BLUEWATER's right to
refuse to accept similarly nonconforming Gas.
11. PRESSURE AND INJECTION/WITHDRAWAL RATES
11.1 Delivery Pressures. BLUEWATER shall deliver Gas to
Customer at pressures sufficient to enter the pipeline facilities at
the Point(s) of Delivery against the operating pressures maintained
by Transporter(s) from time to time. BLUEWATER shall not be
required to deliver Gas at pressures in excess of those required by
Transporter(s) or in excess of Transporter(s) maximum allowable
operating pressure (MAOP), not to exceed 960 psig. Customer shall
deliver or cause to be delivered to BLUEWATER all Gas for wheeling,
parking or injection at the Point(s) of Receipt at pressures not
less than 700 psig and not in excess of the MAOP of BLUEWATER's
facilities at the Point(s) of Receipt. BLUEWATER shall be
responsible for maintaining facilities at such Point(s) of Receipt
to permit Customer to deliver Gas to BLUEWATER at such allowed
pressures.