(a) Be commercially free from objectionable odors, dirt, dust, iron

particles, gums, gum-forming constituents, gasoline, PCBs, and other solid

and/or liquid matter, including but not limited to water, Gas treating

chemicals and well completion fluids and debris, which may become separated

from the Gas during the transportation thereof.

(b) Contain not more than one fourth (1/4) of one grain of hydrogen sulfide per

one

hundred (100) cubic feet, as determined by the cadmium sulfate quantitative

test, nor more than twenty

(20) grains of total sulfur per one hundred (100) cubic feet.

(c) The Gas delivered hereunder shall not contain more than two-tenths of

one percent

(0.2%) by volume of oxygen, shall not contain more than three percent (3%) by

volume of carbon dioxide, shall not contain more than three (3%) by volume of

nitrogen, and shall not contain a combined total of carbon dioxide and nitrogen

components of more than four (4%) by volume.

(d) Have a heating value of not less than nine hundred and sixty-seven

(967) Btus per cubic feet and not more than eleven hundred (1100) Btus per

cubic feet.

(e) Have a temperature of not more than 120 degrees Fahrenheit (120 degrees

F), nor less than forty degrees Fahrenheit (40 degrees F).

(f) Have been dehydrated by the tendering party, by any method other than

the use of a calcium chloride as desiccant, for removal of entrained water in

excess of seven (7) pounds of water per million (1,000,000) cubic feet of Gas

as determined by dew-point apparatus approved by the Bureau of Mines or such

other apparatus as may be mutually agreed upon.

10.2 Rejection of Gas. Either party shall be entitled to reject any Gas

tendered to it by the other party which does not meet the minimum

specifications of Section 10.1 hereunder. Acceptance of such Gas does not

constitute any waiver of Liberty's right to refuse to accept similarly

nonconforming Gas.

11. PRESSURE AND INJECTION/WITHDRAWAL RATES

11.1 Delivery Pressures. Liberty shall deliver Gas to Customer at pressures

sufficient to enter the pipeline facilities at the Point(s) of Delivery located

on Liberty's system against the operating pressures maintained by

Transporter(s) from time to time. Liberty shall not be required to deliver Gas

at pressures in excess of those required by Transporter(s) or in excess of

Transporter(s) maximum allowable operating pressure (MAOP), not to exceed 1,300

psig. Customer shall deliver or cause to be delivered to Liberty all Gas for

wheeling, parking or injection at the Point(s) of Receipt located on Liberty's

system at pressures not less than 800 psig and not in excess of the MAOP of

Liberty's facilities at the Point(s) of Receipt. Liberty shall be responsible

for maintaining facilities at such Point(s) of Receipt to permit Customer to