Black Marlin Pipeline Company
First Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 10/01/1990, Docket: CP89-2041-001, Status: Effective
Original Sheet No. 203 Original Sheet No. 203 : Effective
GENERAL TERMS AND CONDITIONS
(continued)
interference with proper operation of the line, meters,
regulators or other appliances through which it flows;
(b) shall have been dehydrated by Shipper for removal of water
present therein in a vapor state to contain not more than
seven (7) pounds of water vapor per one thousand (1,000)
Mcf, as determined by use of the dew point moisture monitor
apparatus mutually agreed upon; provided, however, Trans-
porter may periodically waive this specification if in Trans-
porter's sole, but reasonable opinion, the receipt of gas
containing more than seven (7) pounds of water vapor per one
thousand (1,000) Mcf will not impair the operation of the
pipeline;
(c) shall contain not more than one quarter (1/4) grain of
hydrogen sulfide per one hundred (100) cubic feet of gas as
determined by a quantitative test mutually agreeable to the
parties hereto after the presence of hydrogen sulfide has
been indicated by qualitative test;
(d) shall contain not more than ten (10) grains of total sulphur
per one hundred (100) cubic feet of gas;
(e) shall contain not more than a combined total of three
percent (3%) by volume of carbon dioxide and/or nitrogen;
(f) shall contain no more than two tenths of one percent (.2%)
by volume of oxygen;
(g) shall have a temperature of not more than one hundred twenty
(120) degrees Fahrenheit; and
(h) shall have a Btu content of not less than nine hundred fifty
(950) per cubic foot.