Centerpoint Energy Gas Transmission Company
Sixth Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 08/27/2008, Docket: RP08-456-000, Status: Effective
First Revised Sheet No. 341 First Revised Sheet No. 341
Superseding: Original Sheet No. 341
GENERAL TERMS AND CONDITIONS
(continued)
4. QUALITY:
4.1 General. Shipper agrees that the Gas tendered for transport
hereunder shall meet the specifications set forth in this section.
Transporter may reject Gas tendered or delivered by Shipper that
fails to conform to the quality specifications provided in this
Tariff or which, in its reasonable judgment, may cause harm to its
facilities or diminish the quality of Gas in its system.
Transporter may under all circumstances subject, or permit the
subjection of, the Gas to compression, cooling, cleaning, products
extraction and other processes.
4.2 Total Heating Value. Gas delivered by Shipper hereunder shall
have a heating value of at least 975 Btu per cubic foot. In the
event that the heating value of the Gas per cubic foot is below
975 Btu, Transporter has the option (a) to refuse to accept said
Gas so long as said heating value remains below 975 Btu per cubic
foot, or (b) to continue to accept delivery of said Gas. The
maximum Btu content of Gas delivered by Shipper shall not exceed
1100 Btu per cubic foot.
4.3 Objectionable Matter. Shipper agrees that the Gas tendered for
transport hereunder:
(a) shall be commercially free from objectionable odors, dust,
impurities, or other solid, gaseous or liquid matter
(including, without limitation, any free water) which might
interfere with its merchantability or cause injury to or
interference with proper operation of the lines, regulators,
meters or other appliances through which it flows;
(b) shall contain less than one fourth (1/4) grain of hydrogen
sulfide per hundred cubic feet of Gas volume;
(c) shall not contain more than five (5) grains in total of
sulphur compounds per hundred cubic feet of Gas volume;