Centerpoint Energy Gas Transmission Company
Sixth Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 02/28/2003, Docket: RP03-239-000, Status: Effective
Original Sheet No. 333 Original Sheet No. 333 : Effective
GENERAL TERMS AND CONDITIONS
(continued)
2. MEASUREMENT:
2.1 Unit of Volume. The unit of volume shall be one Mcf of Gas at a
temperature base of sixty degrees (60() Fahrenheit and a pressure
base of 14.73 psia, and all volumes shall be converted from actual
conditions to these standard bases in accordance with the Ideal
Gas Laws, corrected by Transporter for supercompressibility in
accordance with the American Gas Association ("AGA") Report No. 8,
as amended from time to time, unless otherwise agreed.
2.2 Conversion to Dth. Conversion to Dth shall be made by multiplying
the volume as otherwise determined hereunder by a fraction the
denominator of which is 1,000 and the numerator of which is the
Gross Heating Value of the Gas per cubic foot in British Thermal
Units.
2.3 Quantity and Heating Value Determination. The quantity and heating
value of Gas received and delivered pursuant to a Service
Agreement under the