Algonquin Gas Transmission, LLC
Fifth Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 11/30/2009, Docket: RP10-77-000, Status: Effective
Second Revised Sheet No. 561 Second Revised Sheet No. 561
Superseding: First Revised Sheet No. 561
GENERAL TERMS AND CONDITIONS
(continued)
gas flow, and (ii) a nomination received after the nominations deadline for the
following Gas Day. At least one (1) intra-day nomination can be submitted 4
hours prior to gas flow. Within four (4) hours of an intra-day nomination,
Algonquin will notify affected Customer(s) and point operator(s) of changes in
scheduled quantities. Any scheduling nomination submitted after the initial
scheduling nomination shall contain Customer's anticipated service requirements
for one Day only and shall include the effective date and time. Intra-day
nominations do not replace the remainder of a standing nomination. There is no
need to re-nominate if an intra-day nomination modifies an existing nomination.
The interconnected parties shall agree to the hourly flows for the intra-day
nomination.
If Customer submits an intra-day nomination on the same contract which already
has been scheduled to flow through a Posted Point of Restriction, such intra-day
nomination may be scheduled by Algonquin provided that the intra-day nomination
has a scheduling sequence priority that is being scheduled and allowed to flow on
the same Gas Day as the intra-day nomination pursuant to Sections 23.1 and 48.3
of the General Terms and Conditions and provided that the intra-day nomination
does not result in a net increase in the total volume scheduled on the contract
through the Posted Point of Restriction on that Gas Day.
(d) Elapsed Prorated Scheduled Quantity. With respect to intraday nominations for
reductions in previously scheduled quantities, Algonquin will accept, subject to
the limitations set forth in Sections 22.4(b) and 22.4(c), any explicitly
confirmed quantity, down to and including zero, for such intraday nomination;
provided, however, if such intraday nomination requires confirmation from an
upstream and/or downstream interconnected pipeline then any intraday nomination
to reduce previously scheduled quantities will be subject to, and limited to, the
reduced quantity confirmed by such upstream and/or downstream interconnected
pipeline.
22.5 Minimum NAESB Nomination Standards. In the event the more flexible nomination
procedures set forth in Section 22 above are inapplicable for any reason, nominations
shall be submitted and processed in accordance with the minimum standards set forth in
this Section 22.5. Algonquin shall support the following standard nomination cycles:
(a) The Timely Nomination Cycle: 11:30 am for nominations leaving control of the
nominating party; 11:45 am for receipt of nominations by Algonquin (including
from Title Transfer Tracking Service Providers (TTTSPs)); noon to send Quick
Response; 3:30 pm for receipt of completed confirmations by Algonquin from
upstream and downstream connected parties; 4:30 pm for receipt of scheduled
quantities by Customer and point operator (central clock time on the Day prior to
flow).
(b) The Evening Nomination Cycle: 6:00 pm for nominations leaving control of the
nominating party; 6:15 pm for receipt of nominations by Algonquin (including from
TTTSPs); 6:30 pm to send Quick Response; 9:00 pm for receipt of completed
confirmations by Algonquin from upstream and downstream connected parties; 10:00
pm for Algonquin to provide scheduled quantities to affected Customers and point
operators, and to provide scheduled quantities to bumped parties (notice to