Algonquin Gas Transmission, LLC
Fifth Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 07/01/2004, Docket: RP04-361-000, Status: Effective
Original Sheet No. 527 Original Sheet No. 527 : Effective
GENERAL TERMS AND CONDITIONS
(continued)
6. MEASURING EQUIPMENT (continued)
(c) If no tests have been performed to determine the degree of inaccuracy, or if the
measuring equipment is out of service, the quantity of gas shall be estimated:
(l) By using the registration of any existing and agreed upon check equipment
considered by parties concerned to be registering accurately, or, in the
absence of such facilities,
(2) By correcting the error if the quantity or percentage of error is
ascertainable by calibration, test, or mathematical calculation; or if
neither of the two foregoing procedures is applicable,
(3) By relating the quantity of deliveries to deliveries during periods under
similar conditions when the measuring equipment was deemed to have been
registering accurately.
6.6 Preservation of Records. Each party shall preserve for a period of at least two years
all test data, charts and other similar records.
7. RECEIPT AND DELIVERY PRESSURES
Gas shall be received by Algonquin for the account of Customer at each Point of Receipt
at a pressure sufficient to enter Algonquin's system at the required rate of flow without
requiring a reduction in the pressure on Algonquin's system unless Algonquin, in its reasonable
discretion, expressly agrees to do so in the effective service agreement between Algonquin and
Customer. In no event shall gas be received at a pressure in excess of Algonquin's Maximum
Allowable Operating Pressure.
Algonquin shall deliver gas to Customer at each Point of Delivery at a pressure equal to
or greater than the pressure set forth in the effective service agreement between Algonquin and
Customer, unless otherwise agreed.