4. QUALITY OF GAS
4.1 Composition of Gas. The gas received by Algonquin for Customer's account, or delivered
by Algonquin to Customer, shall be a combustible gas consisting wholly of, or a mixture
of:
(a) Natural gas of the quality and composition produced in its natural state except
that Algonquin may extract or permit the extraction of any of the constituents
thereof except methane.
(b) Gas generated by vaporization of liquefied natural gas (LNG).
(c) Manufactured, reformed, synthesized, or mixed gas consisting essentially of
hydrocarbons of the quality and character produced by nature in the petroleum,
oil, and gas fields with physical properties such that when such gas is commingled
with natural gas, the two become indistinguishable.
4.2 Heating Value and Wobbe Number. Gas received by Algonquin for Customer's account at
each Point of Receipt, or delivered by Algonquin to Customer at the Point(s) of Delivery
shall have a Total Heating Value of at least 967 Btu and not greater than 1,110 Btu per
Cubic Foot of gas volume. The gas shall have a Wobbe Number of not less than 1314 nor
greater than 1400 (calculated using Total Heating Value (THV)), dry, under standard
conditions at 14.73 psia at 60 degrees Fahrenheit based on the following mathematical
definition and in accordance with Section 5 of these GT&C:
THV / Sqrt SGgas
Where:
THV = Total Heating Value (Btu/standard Cubic Foot)
SGgas = Specific Gravity
Sqrt = Square Root of
4.3 Objectionable Properties. The gas received and delivered hereunder:
(a) Shall be commercially free from dust, gum, gum-forming constituents, and free
liquids under continuous gas flow conditions at the pressure and temperature
conditions in Algonquin's pipeline at a point approximately fifty feet in advance
of the interconnection into Algonquin's system that is serving as the Point of
Receipt and the meter inlet header located at or near any Point of Delivery;