Nautilus Pipeline Company, LLC

Original Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 04/05/2010, Docket: RP10-475-000, Status: Effective

First Revised Sheet No. 96 First Revised Sheet No. 96

Superseding: Original Sheet No. 96

 

GENERAL TERMS AND CONDITIONS

 

 

5. MEASUREMENT & MEASUREMENT EQUIPMENT con't

 

(g) When orifice meters are used, the computation of quantities

of Natural Gas delivered shall be in accordance with the

published recommendations of the American Gas Association's

Report No. 3 (ANSI/API 2530), as revised September 1985, and

as such report may be further revised, and any subsequent

amendments thereof, as may be mutually agreed upon by

Shipper and Transporter. Exact measurements of inside

diameters of meter tubes shall be obtained by means of

micrometer to the nearest one-thousandth inch. Said volumes

shall be corrected for flowing temperature and specific

gravity in accordance with the provisions of paragraphs (e)

and (f) above.

 

(h) The total heating value shall be measured, unless otherwise

agreed by Transporter and Shipper, by methods in accordance

with acceptable industry practice such as, but not limited

to, recording calorimeter(s) or Natural Gas chromatograph(s)

located at appropriate points. The arithmetic average of

the heating values recorded each Day and as adjusted to

conditions as specified herein shall be used for

computations.

 

(i) The deviation of the Natural Gas delivered hereunder from

Boyle's and Charles' Laws shall be determined in accordance

with, but not limited to, the published recommendations of

the American Gas Association's Report No. 3, as revised

September 1985, and the American National Standards

Institute as Transporter deems to be in accordance with

accepted industry practice.