13. MEASUREMENT

 

13.1 The unit of volume for measurement of all quantities of Gas wheeled or stored by

Egan Hub or delivered to and received from storage hereunder shall be one (1) Cubic Foot of Gas

at the base temperature of sixty degrees Fahrenheit (60 degrees F) and at an absolute pressure

of fourteen and seventy-three hundredths (14.73) pounds per square inch and dry. All

fundamental constants, observations, records, and procedures involved in determining and/or

verifying the quantity and other characteristics of Gas delivered hereunder shall, unless

otherwise specified herein, be in accordance with the standards prescribed in Report No. 3 of

the American Gas Association, as now and from time to time amended or supplemented. All

measurements of Gas shall be determined by calculation into terms of such unit. All quantities

given herein, unless expressly stated otherwise, are terms of such unit. Notwithstanding the

foregoing, the Btu content of the Gas received and delivered by Egan Hub hereunder shall be

measured on "dry" basis rather than a fully saturated or "wet" basis.

 

13.2 Egan Hub shall install, maintain and operate, or cause to be installed,

maintained and operated, the measurement facilities required hereunder. Said measurement

facilities shall be so equipped with orifice meters, recording gauges, or other types of meters

of standard make and design commonly acceptable in the industry, as to accomplish the accurate

measurement of Gas delivered hereunder. The retrieval of data, calibrating and adjustment of

meters shall be done by Egan Hub or its agent.

 

14. BILLINGS AND PAYMENTS

 

14.1 Invoice. Not later than the ninth (9th) Business Day of each Month, Egan Hub

shall provide Customer (including a Replacement Customer) an invoice and any required backup

data (which may be transmitted by fax) setting forth (i) the charges due for the current Month;

(ii) the total quantity of Gas, stated in dekatherms, received from and delivered to Customer

hereunder during the preceding Month(s), with applicable Point(s) of Receipt and Point(s) of

Delivery properly identified, and the amount due therefor; and if applicable, (iii) the amount

of Customer's Gas in storage as of the close of the preceding Month and information sufficient

to explain and support any adjustments made by Egan Hub in determining the amount billed. Such

invoice shall be delivered to Customer or its agent by posting Customer's final invoice on Egan

Hub's LINK® System and posting a general notice of the availability of the final invoices on

Egan Hub's Informational Postings Web site. Egan Hub will provide an e-mail notification, if

an e-mail address has been designated by Customer, contemporaneously with the posting of the

final invoice on Egan Hub's LINK® System. It is the Customer's responsibility to update e-mail

address information provided to Egan Hub as necessary. Customer may designate an agent to

receive invoices and may designate such agent to receive the e-mail notifications of the

availability of Customer's final invoice on Egan Hub's LINK® System. If actual quantities are

not available by the ninth (9th) Business Day of the Month, Egan Hub may invoice based on best

available data subject to adjustment to actuals at a later date. Quantities at points where

OBAs exist shall be invoiced based on scheduled quantities.