Egan Hub Storage, LLC
First Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 02/01/2009, Docket: RP09-160-000, Status: Effective
Second Revised Sheet No. 129 Second Revised Sheet No. 129
Superseding: First Revised Sheet No. 129
GENERAL TERMS AND CONDITIONS
(Continued)
(c) Preliminary Notifications/Follow-up Reports: Egan Hub shall provide, via
posting on the Internet Web site and to affected parties through the
affected party's choice of Electronic Notice Delivery mechanism(s), prior
notice to all Customers and point operators of upcoming system events such
as anticipated weather patterns and operational problems that may
necessitate the issuance of an Action Alert or OFO.
(d) Applicability of Action Alert or OFO: Egan Hub shall make an Action Alert
or OFO as localized as is reasonably practicable based on Egan Hub's good
faith and reasonable judgment concerning the situations requiring
remediation such that an Action Alert or OFO will be directed first to
Customers and point operators causing the problem necessitating the Action
Alert or OFO and second, if necessary, to all Customers and point
operators. Egan Hub will tailor the Action Alert or OFO to match the
severity of the known or anticipated operational problem requiring
remediation as more fully set forth in subsections 5.5(f) and 5.5(g). The
declaration to the affected parties of Operational Flow Orders, critical
periods and/or Critical Notices shall describe the conditions and the
specific responses required from the affected parties.
(e) Notice: All Action Alerts and OFOs will be issued via posting on the
Internet Web site and to affected parties through the affected party's
choice of Electronic Notice Delivery mechanism(s). Egan Hub shall also
provide such notification via e-mail communication to those Customers and
point operators that have provided e-mail address information for at least
one contact person, and have requested via Egan Hub's Internet Web site, to
receive e-mail notification of Critical Notices issued by Egan Hub. The
Action Alert or OFO will set forth (1) the date and time of issuance, (2)
the actions Customer or point operator is required to take, (3) the time by
which Customer or point operator must be in compliance with the Action
Alert or OFO, (4) the anticipated duration of the Action Alert or OFO, and
(5) any other terms that Egan Hub may reasonably require to ensure the
effectiveness of the Action Alert or OFO. In addition to the other
information contemplated by this Section 5.5(e), such notice shall also
include information about the status of operational variables that
determine when an Action Alert or OFO will begin and end. Egan Hub shall
post periodic updates of such information, promptly upon occurrence of any
material change in the information. Egan Hub will post a notice on the
Internet Web site informing the Customers and point operators when any
Action Alert or OFO in effect will be lifted and specifying the factors
that caused the Action Alert or OFO to be issued and then lifted, to the
extent such factors are known.
(f) Action Alerts: In the event that Egan Hub determines that due to (1) an
ongoing or anticipated weather event, (2) a known equipment problem, or (3)
the anticipated continuation of a current system operational problem,
action is necessary to avoid a situation in which the system integrity is
jeopardized or Egan Hub's ability to render firm service is threatened,
Egan Hub may issue an Action Alert as set out herein to forestall the
development of the situation.
(1) Issuance of Alerts: Action Alerts will be noticed in accord with
the procedures set forth in Section 5.5(e) and Egan Hub will
endeavor to provide a minimum of four hours notice.